Guide & connection service — not a plumbing firm, and it performs no plumbing workEaling, London W5 & W13No telephone number is published for this service — requests go through the form
Emergency Plumber Ealing
The Isolation Register — first isolate, then decide

The guide the whole site hangs on

Stopcock and isolation: where your water turns off, before you ever need it.

Find this valve on a calm day. In Ealing’s older homes it has often not moved in twenty years, and an emergency is the worst time to discover that it has seized, or that it lives behind a fitted kitchen unit.

Stopcock and isolation valves diagramThree valves in a row: the internal stopcock, a quarter-turn lever ball valve, and a gate valve, with arrows showing the direction to close each one. Stopcock: turn clockwise Lever valve: quarter turn across the pipe Gate valve: several turns clockwise
Figure — Three valves you may meet in an Ealing home. If a valve will not move, do not force it with tools: a sheared spindle turns a leak into a flood.

Where the internal stopcock usually is

  • Under the kitchen sink, at the back of the cupboard, on the pipe rising from the floor.
  • In a downstairs cloakroom or utility room, low on the wall where the main enters.
  • Under the stairs, or in a hall cupboard near the front door — the main often enters at the front of a terrace.
  • Behind a bath panel, or in an airing cupboard in some conversions.
  • In converted flats: sometimes one stopcock per flat, sometimes one for the whole house in the ground-floor flat or communal hall. Ask, before you need to know.

How to close it, and prove it worked

  1. Turn clockwise by hand until it stops. Do not use a wrench for extra force.
  2. Open the lowest cold tap in the house. Flow should fall to a trickle and stop. If it does not, you have the wrong valve, a second feed, or a tank still feeding the system.
  3. Label the valve with a tag once you have found it, and tell everyone in the house where it is.
  4. Exercise it twice a year: close it, check, reopen fully, then turn it back a quarter turn so it is less likely to seize open.

If it will not move

Do not force it. A sheared spindle or a cracked body turns a manageable leak into an uncontrolled one. Fall back on the outside stop tap at the property boundary — usually under a small cover in the pavement or front garden, and it may need a stopcock key. That tap is on Thames Water’s communication pipe side of the boundary arrangement and householders do use it in an emergency, but the durable fix is a working internal stopcock: replacing one is a small, plannable job, commonly in the £120 to £260 range in London from the ledger, and far cheaper than the flood it prevents.

Isolating one fitting instead of the whole house

Modern installations have individual isolation valves on the flexible hoses to taps and toilet cisterns — a small slot turned a quarter turn with a flat screwdriver, or a lever. Closing one lets you change a tap washer or a fill valve with the rest of the house still supplied. If your home has none, having them fitted during any other job is money well spent. Note the British terms while you are shopping: it is a tap, not the American word for one, and measurements here are in millimetres and litres.

Tenants and landlords

If you rent, you may turn the water off in an emergency — protecting the property is in everyone’s interest — but repairs to the supply pipe and the plumbing are normally the landlord’s responsibility. Tell the landlord or agent in writing, keep a copy, and keep the photographs.